Changeset 74 for webserver

Show
Ignore:
Timestamp:
10/23/10 22:09:26 (14 years ago)
Author:
phil
Message:

- extended range of hourly queries

Files:

Legend:

Unmodified
Added
Removed
Modified
Copied
Moved
  • webserver/example/EnergyMeters/Source/EnergyMeters/SolarCountUART.c

    r73 r74  
    745745                /* convert and copy value. hourly values must be divided by 60 */ 
    746746                hourRxYield[currentChannel] = 
    747                  ( extractBinaryHexDigitString( &(rxUART3[0]), 13, 16 ) ) / 60; 
     747                 ( extractBinaryHexDigitString( &(rxUART3[0]), 10, 16 ) ) / 60; 
    748748   
    749749            } /* if */